NDET Series Ground Resistance Tester
Contact phone number:
Product Center
-
Series Resonant Withstand Voltage Test Device
-
High-Voltage Withstand Voltage Test Equipment Series
-
Transformer Testing Series
-
Insulating Oil and SF6 Gas Testing Equipment
-
Insulation Resistance and Grounding Resistance Testing Series
-
Instrument transformer, relay, and pressure relief valve testing series
-
Switchgear, Circuit Breaker, and Surge Arrester Testing Series
-
Battery and DC System Testing Series
-
Generator and Motor Testing Series
-
Cable and Overhead Line Inspection Series
-
Secondary Protection Testing Series
-
Partial Discharge-Free Detection and Live On-Line Monitoring Series
-
Power Quality and Safety Tools Testing Series
-
Other
Product Details
Ground resistance · Soil Resistivity Tester It is meticulously designed and manufactured in accordance with the latest standards for lightning protection and grounding resistance testing, specifically for on-site measurements of grounding resistance, soil resistivity, ground voltage, and AC voltage. With a test current of up to 10 mA, it employs digital and microprocessor technologies, enabling precise measurements of grounding resistance using the four‑wire method, the three‑wire method, and the simplified two‑wire method. It also incorporates FFT (Fast Fourier Transform) and AFC (Automatic Frequency Control) technologies. It automatically detects interference and selects the measurement frequency, minimizing its impact and delivering more accurate grounding resistance readings. It features unique anti-interference and environmental adaptability, with excellent repeatability in testing, ensuring high precision, high stability, and high reliability over long-term measurements. It is widely used in electrical applications. Power, telecommunications, meteorology, oilfields, construction, lightning protection, and industrial electrical equipment Measurement of grounding resistance, soil resistivity, ground potential, and AC voltage.
Ground resistance · Soil Resistivity Tester Also known as Precision ground resistance tester, four-wire ground resistance tester, two-, three- and four-wire ground resistance testers, soil resistivity tester , comprising a host unit, data software, test leads, auxiliary grounding rods, communication cables, and other components. The host unit features a dedicated toolbox-style design, using Polypropylene plastic is used as the raw material, with a novel compound added. One-shot injection molding with filler material It boasts lower density and superior strength, stiffness, hardness, wear resistance, heat resistance, and electrical insulation. Its enclosure can withstand pressures of approximately 200 kg, ensuring high precision, stability, and reliability across a wide range of environmental tests. The main unit features an extra-large LCD display with backlighting and bar‑graph indicators for clear, instant readability. Additionally, it can store up to 300 data sets, and dedicated software enables functions such as historical data retrieval, review, saving, report generation, and printing. 。
Merit Can | Ground resistance and soil resistivity testing; ground voltage and AC voltage testing. |
Electricity Source | 11.1V 2600mAh rechargeable lithium battery |
Back Light | Controllable white-screen backlight, ideal for use in low-light environments. |
Measurement method | Precision 4-wire and 3-wire measurement, as well as simple 2-wire measurement of grounding resistance. |
Measurement method | Ground resistance: Rated current pole‑shift method, with a maximum measurement current of 20 mA. |
Soil resistivity: four-electrode method ( Winner method) | |
Ground voltage: Average value rectification ( P(S) - ES Between interfaces) | |
Quantity Cheng | Two‑, three‑, and four‑wire methods for measuring grounding resistance (R): 0.000Ω~200.0kΩ |
Soil resistivity (ρ): 0.000Ωm~9999kΩm | |
Ground voltage: AC 0.001V~600V (50Hz/60Hz) | |
Maximum resolution | Two‑, three‑, and four‑wire methods for measuring grounding resistance (R): 0.001Ω |
Soil resistivity (ρ): 0.01 Ω·m | |
Ground voltage: 0.001V | |
Refined degree | Two‑, three‑, and four‑wire methods for measuring grounding resistance (R): 1. 0.000 Ω to 10.00 kΩ : ±2%rdg±5dgt 2. 10.0K~100.0kΩ : ±3%rdg±5dgt 3. 100.0K~200.0kΩ : ±3.5%rdg±5dgt Note: At an interference voltage of 5 V, the additional error is ≤ ±5% of reading ± 5 digits. |
Soil resistivity (ρ): It depends on the measurement accuracy of R. (ρ=2πaR (a:1 m~100m); π=3.14) | |
Ground voltage: ±2%rdg±5dgt (50Hz/60Hz) | |
Test voltage waveform | Sine wave |
Test frequency | 412 Hz, 825 Hz, 1280 Hz (automatic frequency selection) |
Short-circuit test current | AC 10mA max |
Open-circuit test voltage | AC 90V max |
Electrode spacing range | 1m ~ 100m |
Change 挡 | Ground resistance: 0.000 Ω Ω~ 200k Ω Fully automatic gear shifting |
Soil resistivity: 0.00 Ωm~ 9999k Ωm fully automatic gear shifting | |
LCD | 6 people LCD display, white-screen backlight |
LCD size | 128mm×75mm |
LCD display area | 124mm×67mm |
Measurement indication | During measurement, the LED flashes to indicate status, the LCD displays a countdown, and a progress bar provides visual feedback. |
Size | Instrument dimensions: approximately 320 mm (length) × 275 mm (width) × 145 mm (height) |
Outer packaging dimensions: approximately 400 mm (length) × 245 mm (width) × 335 mm (height) | |
Standard test cable | 4 pieces: 1 red, 15 m; 1 black, 15 m; 1 yellow, 10 m; and 1 green, 10 m. |
Simple test lead | 2 pieces: 1 red 1.6 m and 1 black 1.6 m. |
Auxiliary grounding rod | 4 pieces: approximately phi 10mm×200mm |
Measurement time | Ground voltage: approximately 2 times per second; grounding resistance: approximately 7 seconds per measurement; soil resistivity: approximately 7 seconds per measurement. |
Number of measurements | More than 5,000 cycles (short-circuit test: measure once, pause for 30 seconds, then measure again) |
Line voltage | Measurement below 600 V AC |
Communication interface | Equipped with a USB interface, data can be uploaded to a computer for storage and printing. |
Communication line | One USB communication cable, 1.5 m long. |
Data retention | When preserving data “ HOLD Symbol indication |
Data storage | 300 groups, “ HOLD Storage indication, display “ FULL “Indicates that storage is full” |
Data Retrieval | When viewing data “ READ Symbol indication |
Overflow display | When an overrange overflow occurs “ Office lady Symbol indication |
Interference Testing | Automatically identifies interference signals when the interference voltage exceeds 5 V. NOISE Symbol indication |
Alarm function | When the measured value exceeds the alarm setpoint, a “beep–beep–beep” alarm is triggered. |
Battery voltage | When the battery voltage is low, a low‑battery indicator appears to remind you to recharge the battery. |
Automatic shutdown | If no operation is performed, the device will automatically shut down 15 minutes after being turned on. |
Operating current | Standby: 25 mA max (backlight off); Backlight: 25 mA max (backlight power consumption alone); During measurement: 150 mA max (backlight off) |
Quality Quantity | Instrument: approximately 2.66 kg (including battery) |
Total weight: approximately 6.88 kg (including packaging) | |
Toolbox | Military-grade toolbox design, capable of supporting up to 200 kg. |
Operating temperature and humidity | -10℃ to 40℃; below 80% RH |
Storage temperature and humidity | -20℃ to 60℃; below 70% RH |
Overload protection | Measuring ground resistance: C (H) -E、 P (S) -ES AC 280V for 3 seconds between each port |
Insulation resistance | Greater than 20 MΩ (500 V between the circuit and the enclosure) |
Durability Pressure | AC 3700 V/rms (between circuit and enclosure) |
Electromagnetic properties | IEC61326 (EMC) |
Suitable for safety regulations | IEC 61010-1 (CAT III 300 V, CAT IV 150 V, Pollution Degree 2); IEC 61010-031; IEC 61557-1 (Earth Resistance); IEC 61557-5 (Soil Resistivity); JJG 366-2004 (Earth Resistance Meter) |
Service system
Offering inspection and reception services
We guarantee to welcome your visit at any time and provide you with every possible convenience.
Provide a reasonable quotation.
We guarantee to provide a unified, reasonable quotation for the products you request within 24 hours.
Provide professional technical support
We guarantee that a technical specialist will respond to any technical questions you may have within 24 hours.
Provide detailed information
We guarantee that, within 24 hours, the product catalogues, software CDs, and other technical materials you require will be delivered to your company by our local branch or office.
Related products
Power Technology
2016-04-05
Leave a message for inquiry
Contact Us
National Service Hotline: 400-027-8938
Mobile (Manager Chen): 133 9714 9829
Address: Building No. 5, Donghu High-tech Industrial Innovation Base, No. 9 Miaoshan Avenue, Miaoshan Development Zone, Jiangxia District, Wuhan City
Scan it
Follow the official mobile website