ND7880 Series Transformer Oil Furfural Analyzer (including high-pressure infusion pump, UV–Vis spectrophotometric detector, and shaker)
Contact phone number:
Product Center
-
Series Resonant Withstand Voltage Test Device
-
High-Voltage Withstand Voltage Test Equipment Series
-
Transformer Testing Series
-
Insulating Oil and SF6 Gas Testing Equipment
-
Insulation Resistance and Grounding Resistance Testing Series
-
Instrument transformer, relay, and pressure relief valve testing series
-
Switchgear, Circuit Breaker, and Surge Arrester Testing Series
-
Battery and DC System Testing Series
-
Generator and Motor Testing Series
-
Cable and Overhead Line Inspection Series
-
Secondary Protection Testing Series
-
Partial Discharge-Free Detection and Live On-Line Monitoring Series
-
Power Quality and Safety Tools Testing Series
-
Other
Product Details
■Features and Benefits
The high-pressure infusion pump is a tandem reciprocating pump with two pistons, offering high flow accuracy.
The floating-type guide plunger rod mounting method, combined with carefully selected high‑quality plunger rods and sealing rings—key components—ensures the infusion pump’s long‑term operational stability and durability under high pressure.
Dual correction functions for mobile-phase compressibility and flow-rate accuracy, enabling adjustments of ± according to differences in the solvent system. 15% Velocity error compensation is performed within the measurement range, ensuring exceptionally high flow accuracy.
Through RS-485 External control via a chromatography workstation enables the convenient implementation of a high-precision binary high-pressure gradient system, while also allowing for flow-rate gradients of the mobile phase, thereby meeting diverse requirements in both production and research.
Real-time pressure monitoring, high-pressure and low-pressure limit alarms ensure the safe operation of the instrument.
The high‑flow flushing and solvent‑replacement function reduces solvent‑exchange time and enhances operational efficiency.
With OLED The module features a user-friendly human-machine interface, offering convenient and flexible operation.
■Performance Metrics
Technical Specifications of Analytical Pumps
Flow range: 0.001mL/min ~ 10.00mL/min
Flow accuracy: ≤± 2%
Traffic Stability: RSD ≤ 2%
Maximum working pressure: 42MPa ( 0.01mL/min ~ 10.000mL/min ) (Default highest 90% )
Pressure pulsation: < 0.1MPa (Traffic 1 mL/min, Pressure 5MPa ~ 10MPa )
Power Supply: AC 110V/220V ,50Hz/60Hz
Power consumption: 100W
External dimensions (Length × Width × Height): 400mm × 180mm × 300mm/10.0kg
■Instrument Features
- Advanced optical unit design;
The detector’s optical system incorporates a novel design concept. As is well known, the operating principle of UV detectors is based on the Lambert–Beer law; accordingly, we have focused on optimizing the optical path to ensure that the photodiodes in both the sample and reference paths receive the maximum possible light intensity.

Among them, I1 For the light intensity of the sample path, I0 where I₀ is the reference light intensity, and ε is the molar absorptivity. L It is the optical path length of the flow cell.
Key improvements:
- Light source 2 ) Optical path
- A newly designed filter 4 ) Uses a holographic grating
- A brand-new flow cell;
- The overall digital signal processing and control system;
The newly designed integrated voltage system ensures more stable power supply and is suitable for use in explosion-proof environments.
■ Key Technical Specifications
Large-screen LCD display: (240 x 128 dot-matrix LCD)
Temperature control range: room temperature to 120°C
Temperature control method: Digital PID automatic control
Temperature control accuracy: Room temperature to 50°C ±0.2°C;
50℃–100℃ ±0.3℃;
100℃–120℃ ±0.5℃;
Oscillation frequency: 275 ± 3 cycles per minute
Oscillation amplitude: 35 mm
Sample volume: 5 × 100 mL syringes;
Four 250 mL Erlenmeyer flasks;
Working modes: 4 modes
1. Chromatographic degassing by shaking: constant temperature of 50°C;
Shake for 20 minutes; let stand for 10 minutes;
2. Water-soluble acid shaking: constant temperature of 75°C;
Oscillation 5 minutes; stationary 0 minutes;
3. Other physical oscillations: Constant temperature, arbitrarily set between 0 and 120°C;
Oscillation can be set arbitrarily between 0 and 99 minutes;
Set the idle time arbitrarily between 0 and 99 minutes;
4. Manually start oscillation and manually stop oscillation
Operating voltage: AC 220 V ± 20%;
Power supply frequency: 50 Hz ± 5%;
Maximum power consumption: 800 VA;
Ambient temperature: 10°C–40°C;
Ambient humidity: ≤85%;
External dimensions: 500 x 350 x 385;
Weight: 35
Service system
Offering inspection and reception services
We guarantee to welcome your visit at any time and provide you with every possible convenience.
Provide a reasonable quotation.
We guarantee to provide a unified, reasonable quotation for the products you request within 24 hours.
Provide professional technical support
We guarantee that a technical specialist will respond to any technical questions you may have within 24 hours.
Provide detailed information
We guarantee that, within 24 hours, the product catalogues, software CDs, and other technical materials you require will be delivered to your company by our local branch or office.
Related products
Power Technology
2016-04-05
Leave a message for inquiry
Contact Us
National Service Hotline: 400-027-8938
Mobile (Manager Chen): 133 9714 9829
Address: Building No. 5, Donghu High-tech Industrial Innovation Base, No. 9 Miaoshan Avenue, Miaoshan Development Zone, Jiangxia District, Wuhan City
Scan it
Follow the official mobile website