ND7860 Series Transformer Oil Chromatography Analyzer
Contact phone number:
Product Center
-
Series Resonant Withstand Voltage Test Device
-
High-Voltage Withstand Voltage Test Equipment Series
-
Transformer Testing Series
-
Insulating Oil and SF6 Gas Testing Equipment
-
Insulation Resistance and Grounding Resistance Testing Series
-
Instrument transformer, relay, and pressure relief valve testing series
-
Switchgear, Circuit Breaker, and Surge Arrester Testing Series
-
Battery and DC System Testing Series
-
Generator and Motor Testing Series
-
Cable and Overhead Line Inspection Series
-
Secondary Protection Testing Series
-
Partial Discharge-Free Detection and Live On-Line Monitoring Series
-
Power Quality and Safety Tools Testing Series
-
Other
Product Details
■ Product Overview
The transformer oil chromatography analyzer is suitable for determining the concentrations of dissolved gas components in insulating oil used in power systems, and a single injection is sufficient to analyze the dissolved gases in the insulating oil. 7 Gas component species H2、 CO 、CO2、CH4、C2H4、C2H6、 C2H2( Hydrogen, carbon monoxide, carbon dioxide, methane, ethylene, ethane, acetylene ) A comprehensive analysis of the content, with a minimum detection limit for acetylene reaching 0.1ppm . [Main Testing] :H2 、 CO 、CO2、CH4、C2H4、C2H6、C2H2 As the primary basis for fault diagnosis , It is recommended to test whenever possible. :02 、N2 As an auxiliary judgment ( That is 9 Type of gas )。
■ Product Ingredients
Name | Component | Minimum detection concentration /uL/L |
Methane | CH4 | 0.1 |
Ethylene | C2H4 | 0.1 |
Ethane | C2H6 | 0.1 |
Acetylene | C2H2 | 0.1 |
Hydrogen gas | H2 | 2 |
Carbon monoxide | CO | 1 |
Carbon dioxide | CO2 | 5 |
■Product Features
1. Online monitoring H2、 CO 、CH4、C2H4、C2H6、C2H2、CO2、 H20( Optional equipment ) Gas concentration and growth rate :
2. Rapid analysis cycle, with a minimum monitoring interval of 1 hour , Longest 30 Heaven , Users can configure it themselves. ( Recommended as 24 hour )
3. A cyclic sampling method is employed, thereby avoiding any loss of transformer oil due to discharge. ;
4. A vacuum environment and magnetic stirring are employed to achieve rapid oil–gas separation, with a stable degassing rate. ;
5. Employing an exclusive patented cold-trap technology, it completely isolates hydrocarbon contamination, enabling maintenance-free operation of on-site equipment throughout its entire service life.
6. By employing a dedicated high-performance monolithic chromatographic column, the system’s analytical reliability is enhanced, making it suitable for the long-term safe operation of field‑based outdoor equipment.
7. Adopting internationally advanced MEMS Integrated sensor technology, with high detection sensitivity, long service life, and a stable baseline. ;
8. High-stability, high-precision gas detection technology and computational models, with an error margin of ± 10% , superior to offline chromatographs ± 30% of the indicator
9. Adopt TCP/IP Network protocol that enables remote monitoring and diagnostics, as well as remote data browsing and access. ;
10. Automatically identify peak positions in fault gas characteristic curves and perform analysis of the raw spectra.
11. Multiple data display and query methods are provided, along with data reporting and trend chart analysis.
12. Provides multiple fault diagnosis methods, including the improved three-ratio method, the David triangle method, and the cubic diagram method.
13. Equipped with an equipment anomaly alarm function, it significantly enhances the reliable and safe operation of the equipment. ;
14. Installation and maintenance are straightforward; the entire equipment can be installed live without disrupting the transformer’s normal operation.
■ Product Specifications
Technical Specifications | Detailed specifications |
Hydrogen Flame Ionization Detector | Detection limit :Mt ≤ 3x10-12 g/s( n-Hexadecane - Isooctane solution ) |
Noise : ≤ 5x10-14A | |
Drifting : ≤ 1x10-13A/30min | |
Linear range : ≥ 106 | |
Thermal Conductivity Detector | Sensitivity :S ≥ 3500 mV/mI/mg( Routine )5000 mV/mL/mg( High sensitivity ) |
Noise : ≤ 10 mu V | |
Baseline drift : ≤ 30 mu V/30min | |
Linear range : ≥ 104 | |
Column oven temperature control | Temperature control range : Above room temperature 4~450 °C |
Temperature control accuracy : ± 0.1 °C | |
Packed-column injector | Temperature control range : Above room temperature 4~450 °C |
Temperature control accuracy : ± 0.1 °C | |
Hydrogen flame (FID) Detector | Temperature control range : Above room temperature 4~450 °C |
Temperature control accuracy : ± 0.1 °C |
■Product Selection Specification Table
Model number | Functional Parameters |
ND7860 | Headspace sampler model ,H2 、 CO 、CO2、CH4、C2H4、C2H6、 C2H2(7 seed ) |
ND7861 | ( For ethylene oxide use only ) Fully automatic type |
ND7862 | ( For ethylene oxide use only ) Semi-automatic type |
ND7863 | Nine-component methane CH4 Ethylene C2H4 Ethane C2H6 Acetylene C2H2 Hydrogen gas H2- Carbon monoxide CO Carbon dioxide C02 Oxygen 02 Nitrogen gas N2 |
Service system
Offering inspection and reception services
We guarantee to welcome your visit at any time and provide you with every possible convenience.
Provide a reasonable quotation.
We guarantee to provide a unified, reasonable quotation for the products you request within 24 hours.
Provide professional technical support
We guarantee that a technical specialist will respond to any technical questions you may have within 24 hours.
Provide detailed information
We guarantee that, within 24 hours, the product catalogues, software CDs, and other technical materials you require will be delivered to your company by our local branch or office.