NDXB-H Series Power-Frequency Inductive Reactance Generator AC Withstand Voltage Test Equipment
Contact phone number:
Product Center
-
Series Resonant Withstand Voltage Test Device
-
High-Voltage Withstand Voltage Test Equipment Series
-
Transformer Testing Series
-
Insulating Oil and SF6 Gas Testing Equipment
-
Insulation Resistance and Grounding Resistance Testing Series
-
Instrument transformer, relay, and pressure relief valve testing series
-
Switchgear, Circuit Breaker, and Surge Arrester Testing Series
-
Battery and DC System Testing Series
-
Generator and Motor Testing Series
-
Cable and Overhead Line Inspection Series
-
Secondary Protection Testing Series
-
Partial Discharge-Free Detection and Live On-Line Monitoring Series
-
Power Quality and Safety Tools Testing Series
-
Other
Product Details
■Product Overview
Large-scale thermal and hydroelectric generators, owing to their substantial ground capacitance, require a very high test capacity during AC withstand voltage testing. When employing a variable-frequency resonant system for such tests, the demands on the variable-frequency power supply are extremely stringent; at present, most domestic testing facilities rely on resonant transformers to conduct these trials. , However, resonant transformers are inherently very heavy—often weighing several tons—making on-site testing quite inconvenient. In response to this challenge, our company has designed and manufactured a specialized inductance‑tuning generator‑based AC withstand voltage resonant boost system. This series of equipment employs a parallel configuration of multiple reactor sections; by adjusting the inductance of the tunable reactor and paralleling fixed reactors of varying numbers, it achieves resonance. The specific configuration is selected according to the required test capacity. , Reasonably configure fixed and adjustable reactors of different ratings. , Thereby minimizing the power supply capacity and the size and weight of the test equipment.
■ Product Features
When performing AC withstand voltage tests on generators of the same voltage level and capacity, the overall equipment weight is significantly reduced; the weight of each individual unit is only a fraction of that of conventional equipment. 1/5, Completely resolve the issue of on-site handling difficulties.
The entire system features a state-of-the-art operating principle and incorporates an advanced casting process. The complete setup adopts a dry‑type design and employs precision‑machined transmission components, significantly reducing operational noise.
Equipped with a dry-type columnar voltage regulator, it delivers excellent output waveform and superior stability. ;
The excitation transformer features dual high- and low-voltage outputs; when equipped with a rectifier silicon stack, it can also perform DC withstand voltage tests on the generator.
The inductance values of both fixed and adjustable reactors are optimally configured, ensuring favorable resonance points for test specimens with varying capacitances and eliminating any resonance dead zones.
The operating system not only enables adjustment of voltage and inductance but also provides real-time monitoring of the circuit’s power factor, high‑voltage side current, high‑voltage test voltage, low‑voltage output, and air‑gap lift; it further incorporates overcurrent and overvoltage protection.
■Product Specifications
Rated output voltage | 0~60kV(AC Valid value ) and below |
Output frequency | 50Hz |
Resonant voltage waveform | Pure sine wave, waveform distortion rate ≤ 1% |
Work system | Continuous operating time at full power 1min |
Quality factor | 10~40 |
Maximum test capacity | 3000kVA and below |
Power supply | 380V+15% , power frequency 50Hz |
■Reference Table of Electrical Capacitance for Commonly Used Hydroelectric Generators in Power Systems
Category | Generator parameters | ||
Thermal power generator | Rated capacity MW | Rated voltage kV | Phase capacitance μ F |
72.5-85 | 10.5 | 0.694 | |
125-150 |
| 1.8-1.9 | |
300 | 15.75 | 1.7-2.5 | |
400 | 18.0 | 2-2.5 | |
600 |
| 2.1-2.5 | |
■Product Series Configuration and Application Scope
Product Model Name | Scope of Application ( Output voltage 20kV AC withstand voltage test for generators or motors at the specified voltage level and below; product model name; test frequency. :50Hz) | |||||
Console | Voltage regulator | Reactor ( Dry type ) | Excitation transformer ( Dry type ) | Voltage divider | Scope of Application
| |
200/25 | 30kW | 30kVA ( Electric ) | 200kVA/25kV Adjustable one unit | 30kVA ( Dry type ) | 30kV | Hydroelectric generator 0.4~1.0 mu F(10kV/40MW) |
300/50 | 60kW | 6OkVA ( Electric ) | 300kVA/50kV Adjustable one unit | 60kVA ( Oil-immersed ) | 50kV | Thermal power generator 0.27~0.33 mu F (20kV/300MW) |
600/50 | 60kW | 60kVA ( Electric ) | 200kVA/50kV Adjustable one unit 400kVA/50kV Adjustable one unit | 60kVA ( Oil-immersed ) | 50kV | Thermal power generator 0.113~0.45 mu F (20kV/600MW) |
1200/50 | 120kW | 120kWA ( Induction ) | 200kVA/50kV Secure two units 800KVA/50kV Adjustable one unit | 120kVA ( Oil-immersed ) | 50kV | Hydroelectric generator 0.6~1.8uF(20kV/250MW) |
2750/55 | 300kW | 300kWA ( Induction ) | 750KVA55kV Secure two units 1250kVA/55kV Adjustable one unit | 300kVA ( Oil-immersed ) | 60kV | Hydroelectric generator 1.6~3.3 mu F(20kV1770MW) |
Note : Solutions can be customized based on the parameters of the test specimen.
Service system
Offering inspection and reception services
We guarantee to welcome your visit at any time and provide you with every possible convenience.
Provide a reasonable quotation.
We guarantee to provide a unified, reasonable quotation for the products you request within 24 hours.
Provide professional technical support
We guarantee that a technical specialist will respond to any technical questions you may have within 24 hours.
Provide detailed information
We guarantee that, within 24 hours, the product catalogues, software CDs, and other technical materials you require will be delivered to your company by our local branch or office.
Related products
Power Technology
2016-04-05
Leave a message for inquiry
Contact Us
National Service Hotline: 400-027-8938
Mobile (Manager Chen): 133 9714 9829
Address: Building No. 5, Donghu High-tech Industrial Innovation Base, No. 9 Miaoshan Avenue, Miaoshan Development Zone, Jiangxia District, Wuhan City
Scan it
Follow the official mobile website