NDXB-Y Series AC Withstand Voltage Resonant Test System for Power Cables (Oil-Immersed Type)
Contact phone number:
Product Center
-
Series Resonant Withstand Voltage Test Device
-
High-Voltage Withstand Voltage Test Equipment Series
-
Transformer Testing Series
-
Insulating Oil and SF6 Gas Testing Equipment
-
Insulation Resistance and Grounding Resistance Testing Series
-
Instrument transformer, relay, and pressure relief valve testing series
-
Switchgear, Circuit Breaker, and Surge Arrester Testing Series
-
Battery and DC System Testing Series
-
Generator and Motor Testing Series
-
Cable and Overhead Line Inspection Series
-
Secondary Protection Testing Series
-
Partial Discharge-Free Detection and Live On-Line Monitoring Series
-
Power Quality and Safety Tools Testing Series
-
Other
Product Details
■Product Overview
Used for 10kV、35kV、110kV For AC withstand voltage testing of cables, the variable-frequency series resonance withstand test utilizes the inductance of a reactor and the capacitance of the device under test to achieve capacitive resonance, thereby generating high voltage and large current across the test specimen. The AC withstand voltage test system for cables primarily consists of a variable-frequency power supply. ( Host ) It consists of an excitation transformer, a reactor, and a capacitive voltage divider.
The frequency adjustment range is 30~300Hz , in compliance with the enterprise standards issued by China Southern Power Grid Company ( The “Regulations for Preventive Testing of Power Equipment” can not only meet the requirements of high-voltage… XLPE It meets the voltage withstand requirements for cables and is lightweight. ( The weight of a single component shall not exceed 30kg) Its excellent portability makes it well suited for field testing.
■ Common Configuration Table for Variable-Frequency Resonance in AC Withstand Voltage Testing of Cables
35kV Configuration Table for Withstand Voltage Testing Equipment for Cables of 1 kV and Below | |||||
Model Name | Control box | Reactor | Excitation transformer | Voltage divider | Scope of Application |
NDXB-F - 44/22 | 2.5kW | 1A/22kV Two units | 2.5KVA/1kV | 25kV | 10kV Cable ≤1km |
ND XB-F- 88/22 | 4kW | 2A/22kV Two units | 4KVA/1kV | 25kV | 10kV Cable ≤2km |
NDXB-F - 132/22 | 6kW | 2A/22kV Three units | 6KVA/1/3kV | 60kV | 10kV Cable ≤3km 35kV Cable ≤1km |
NDXB-F - 176/22 | 7.5kW | 2A/22kV Four units | 7.5KVA/3kV | 60kV | 10kV Cable ≤4km 35kV Cable ≤1km |
NDXB-F - 264/22 | 10kW | 2A/22kV Six units | 10KVA/1/3kV | 60kV | 10kV Cable ≤6km 35kV Cable ≤2km |
NDXB-F - 330/22 | 15kW | 2.5A/22kV Six units | 15KVA/1kV | 100kV | 10kV Cable ≤8km 35kV Cable ≤2km |
NDXB-F - 640/22 | 25kW | 2A/22kV Eight units | 25KVA/1/3/5kV | 200kV | 10kV Cable ≤10km 35kV Cable ≤4km 110kV Cable ≤1km |
110kV Configuration Table for Withstand Voltage Testing Equipment for Cables of 1 kV and Below | |||||
Model Name | Control box | Reactor | Excitation transformer | Voltage divider | Scope of Application |
NDXB-F- 1300/130 | 50kW | 5A/130kV Two units | 505KVA/1/3/5kV | 150kV | 35kV Cable ≤2km 110kV Cable ≤2km |
NDXB-F- 260/130 | 100kW | 5A/130kV Four units | 100KVA/1/3/5/10kV | 220kV | 35kV Cable ≤3km 110kV Cable ≤3km 220kV Cable ≤1.5km |
NDXB-F- 3200/220 | 160kW | 4A/220kV Four units | 160KVA/5/10kV | 220kV | 110kV Cable ≤5km 220kV Cable ≤3km |
NDXB-F-6400/220 | 320kW | 8A/220kV Four units | 320KVA/5/10kV | 320kV | 110kV Cable ≤10km 220kV Cable ≤5km 500kV Cable ≤1km |
■ Product Specifications
Rated output voltage | 0~220kV |
Output frequency | 30~300Hz |
Resonant voltage waveform | Pure sine wave, waveform distortion rate ≤ 1.0% |
Full-load operating time | Continuous working hours 60min |
Quality factor | 30~90 |
Frequency adjustment sensitivity | 0.1Hz |
Instability degree | <0.05% |
Power supply | Single-phase 220V or three-phase 380V ± 15% , power frequency 50Hz ± 5% |
■Product Features
Easy to operate : Automatic tuning ( Automatic resonance point search ) , Automatic Testing ( Automatic resonance point tracking and automatic voltage boosting ) and manual testing ( Manually searching for the resonance point and manually boosting the voltage ) The three modes cater to different test requirements. They allow adjustment of the test voltage, frequency‑modulation range, protection current, and pressurization time.
Automatic mode : Simply set the test voltage and duration; the equipment automatically and precisely adjusts frequency and voltage, completes the test, and saves the data.
It features ground fault and flashover protection.
It can automatically track changes in grid voltage and adjust the voltage in real time, ensuring stable high-voltage levels.
Easy to operate ; Single-phase 220V Or three-phase 380V The power supply is universal, making on-site power access convenient.
Reactors of the same voltage level and capacity are smaller in size and lighter in weight. ; The temperature rise is small under rated load. ; Adopting dry-type epoxy casting , High mechanical strength and excellent electrical insulation properties. , Beautiful and can be concealed.
Flexible configuration : The reactor can be connected in series. / It can be used in parallel to meet the requirements of various test specimens, enabling multi‑purpose operation with high cost‑effectiveness.
Service system
Offering inspection and reception services
We guarantee to welcome your visit at any time and provide you with every possible convenience.
Provide a reasonable quotation.
We guarantee to provide a unified, reasonable quotation for the products you request within 24 hours.
Provide professional technical support
We guarantee that a technical specialist will respond to any technical questions you may have within 24 hours.
Provide detailed information
We guarantee that, within 24 hours, the product catalogues, software CDs, and other technical materials you require will be delivered to your company by our local branch or office.
Related products
Power Technology
2016-04-05
Leave a message for inquiry
Contact Us
National Service Hotline: 400-027-8938
Mobile (Manager Chen): 133 9714 9829
Address: Building No. 5, Donghu High-tech Industrial Innovation Base, No. 9 Miaoshan Avenue, Miaoshan Development Zone, Jiangxia District, Wuhan City
Scan it
Follow the official mobile website