NDLS-6OA SF6 Gas Online Monitoring System
Contact phone number:
Product Center
-
Series Resonant Withstand Voltage Test Device
-
High-Voltage Withstand Voltage Test Equipment Series
-
Transformer Testing Series
-
Insulating Oil and SF6 Gas Testing Equipment
-
Insulation Resistance and Grounding Resistance Testing Series
-
Instrument transformer, relay, and pressure relief valve testing series
-
Switchgear, Circuit Breaker, and Surge Arrester Testing Series
-
Battery and DC System Testing Series
-
Generator and Motor Testing Series
-
Cable and Overhead Line Inspection Series
-
Secondary Protection Testing Series
-
Partial Discharge-Free Detection and Live On-Line Monitoring Series
-
Power Quality and Safety Tools Testing Series
-
Other
Product Details
Technical Features
- In the environment Science Fiction 6 Gas concentration detection function
- Environmental oxygen concentration detection function
- Environmental temperature and humidity monitoring function
- Real-time display of telemetry and remote signaling data from all monitoring points in the environment.
- Real-time display of alarm information from all monitoring points in the environment.
- Setpoint Adjustment Function
- Science Fiction 6 Gas concentration over-limit and oxygen deficiency alarm functions
- Hypoxia or Science Fiction 6 Excessive concentration, forced ventilation function
- Automatic fan start-up upon alarm activation
- Automatic timed ventilation function
- Manually force all fans to start or stop. ,
- Historical data query, display, and storage functions
- Historical trend query and display function for telemetry values
- Enter GIS Room automatic broadcast of the current environmental status feature
- Multi‑monitoring‑point configuration feature for different regions
- Multi-point networking functionality enables integration with communication protocols and substation backend databases. ( Reserved )
- Provides a universal communication interface and includes provisions for integration with backend monitoring and fire‑protection systems. ( Reserved )
- Alarm information storage and recording function
- Audio-visual and voice alarm functions
- Remote alarm function
- Human body infrared detection and sensing function
- Remote Data Transmission Function
1.4 Technical Specifications
- Operating voltage: AC/DC 220V ± 10%, 50 Hz
- Power Consumption: Less than under rated voltage 10W
- Accuracy class: 2.5 level
- Science Fiction 6 Gas concentration measurement range: 0-3000ppm
- Science Fiction 6 Concentration Overlimit Alarm Point: 1000ppm (National standard value), accuracy < 5%FS
- Oxygen content detection range: 0-25%
- Hypoxia alarm threshold: 18% (National standard value), accuracy < 1%FS
- Temperature detection range: -30 — +99 °C ( Accuracy ± 0.5 °C )
- Humidity detection range: 10-99%RH : Accuracy ± 0.5 % Human Resources
- Wind turbine output power connection: 6 A ;
- Remote communication method: 485/Ethernet
- On-site host external dimensions (mm) :L330 × W250 × H65
- Science Fiction 6 and the dimensions of the oxygen detection unit (mm) :L162 × W150 × H38
- Dimensions of the temperature and humidity sensing unit (mm) :L162 × W150 × H38
- Monitoring historical data storage capacity: 500 Ten thousand items;
- Touchscreen size: 7 inch
- Mounting method for the host and detection unit: wall-mounted.
- Operating ambient temperature: -25 °C~ 70 °C
- Operating environment humidity: ≤ 95 %
- According to GB/T 17626 The regulations and methods for testing the electromagnetic compatibility performance indicators of this device are as follows:
Electrostatic discharge, 4 level
Radio-frequency electromagnetic field immunity, 3 level
Electrical fast transient burst immunity, 4 level
Surge (impulse) immunity, 4 level
Conducted immunity to radio-frequency field-induced disturbances, 3 level
Power-frequency magnetic field immunity, 5 level
Pulse magnetic field immunity, 5 level
Damped oscillatory magnetic field immunity, 5 level
Voltage sag and short-duration interruption immunity, 60%UT , continuous 10 one cycle;
- According to GB/T 11287 、 GB/T 14573 The regulations and methods for testing the mechanical performance parameters of this device are as follows:
Vibration response, 1 level
Vibration resistance, 1 level
Impact response, 1 level
Impact durability, 1 level
Collision, 1 level
Service system
Offering inspection and reception services
We guarantee to welcome your visit at any time and provide you with every possible convenience.
Provide a reasonable quotation.
We guarantee to provide a unified, reasonable quotation for the products you request within 24 hours.
Provide professional technical support
We guarantee that a technical specialist will respond to any technical questions you may have within 24 hours.
Provide detailed information
We guarantee that, within 24 hours, the product catalogues, software CDs, and other technical materials you require will be delivered to your company by our local branch or office.
Related products
Power Technology
2016-04-05
Leave a message for inquiry
Contact Us
National Service Hotline: 400-027-8938
Mobile (Manager Chen): 133 9714 9829
Address: Building No. 5, Donghu High-tech Industrial Innovation Base, No. 9 Miaoshan Avenue, Miaoshan Development Zone, Jiangxia District, Wuhan City
Scan it
Follow the official mobile website