NDJXPDF Series DC System Insulation Monitoring Device Calibrator
Category:
Contact phone number:
Product Center
-
Series Resonant Withstand Voltage Test Device
-
High-Voltage Withstand Voltage Test Equipment Series
-
Transformer Testing Series
-
Insulating Oil and SF6 Gas Testing Equipment
-
Insulation Resistance and Grounding Resistance Testing Series
-
Instrument transformer, relay, and pressure relief valve testing series
-
Switchgear, Circuit Breaker, and Surge Arrester Testing Series
-
Battery and DC System Testing Series
-
Generator and Motor Testing Series
-
Cable and Overhead Line Inspection Series
-
Secondary Protection Testing Series
-
Partial Discharge-Free Detection and Live On-Line Monitoring Series
-
Power Quality and Safety Tools Testing Series
-
Other
Product Details
- Features and Benefits
- Insulation monitoring devices or portable ground-fault locators can be calibrated online or offline.
- The device is equipped with a positive‑grounding test function, enabling verification of both the accuracy of the positive‑grounding test and the accuracy of the positive‑grounding alarm for the device under test.
- The device is equipped with a negative‑grounding test function, enabling verification of both the accuracy of the negative‑grounding test and the accuracy of the negative‑grounding alarm for the device under test.
- The device features a two‑pole grounding test function, enabling verification of the tested equipment’s two‑pole grounding performance and assessment of the accuracy of its two‑pole grounding alarm.
- The device features voltage‑accuracy testing capabilities and incorporates an adjustable DC voltage source. Users can configure multiple test points to evaluate the voltage measurement accuracy of the device under test.
- The device is equipped with an AC‑injection test function, enabling verification of the AC‑injection detection capability of the device under test.
- The device features a system‑wide distributed capacitance testing capability, allowing users to configure and set the positive‑to‑ground impedance, negative‑to‑ground impedance, positive‑to‑ground distributed capacitance, and negative‑to‑ground distributed capacitance.
- The device features branch‑level testing for distributed capacitance, allowing users to configure and set the positive‑to‑ground impedance, negative‑to‑ground impedance, positive‑to‑ground distributed capacitance, and negative‑to‑ground distributed capacitance of each branch.
- The device features signal analysis capabilities; for equipment that requires signal‑based ground‑fault detection, this function enables the analysis of parameters such as signal amplitude, frequency, and power of the device under test.
- The device features an electrical bridge safety‑check function; using this feature, users can determine whether the bridge is safe by comparing the ratio of the measured device’s negative-to-ground voltage to its positive-to-ground voltage.
- The device features DC cross‑connection and DC ring‑closing test functions; users can configure various types of DC cross‑connection or ring‑closing scenarios to verify the tested device’s DC cross‑connection and ring‑closing detection capabilities.
- The device features a branch‑line selection test function, allowing users to configure combinations of positive‑pole ground impedance, negative‑pole ground impedance, system distributed capacitance, and branch‑line distributed capacitance, and to input the results of branch‑line selection.
- The device features a false‑trip test function, allowing users to configure combinations of insulation resistance, bridge resistance, system distributed capacitance, and branch‑circuit distributed capacitance to verify the false‑trip detection capability of the device under test.
- Test portable ground-fault location products and conduct safety assessments.
- The measurement displays and saves the waveform of ground voltage variations.
- Capable of conducting on-site analysis and testing of protection maloperations caused by ground faults in DC systems.
It can generate and export test reports, and save test data.
Main Technical Specifications
- Operating environment
- Power supply: AC 220 V ±15%
- Ambient temperature: -20℃ to 45℃
- Relative humidity: 5–90%
- Power supply: AC 220 V ±15%
- DC power supply
- DC power output: 20–260 V, adjustable
- The maximum output current is 1.2 A.
- Internal Power Supply: Provides two independent output channels.
- Ripple factor: ≤1%
- DC power output: 20–260 V, adjustable
- AC Power Parameters
- Output voltage levels: AC 50 V / 110 V / 220 V; maximum output current: 500 mA.
- Output voltage levels: AC 50 V / 110 V / 220 V; maximum output current: 500 mA.
- DC Voltage Measurement
- DC voltage measurement resolution: 0.1 V
- Voltage measurement accuracy: ≤0.5%
- DC voltage measurement resolution: 0.1 V
- Positive and negative electrode insulation resistance parameters
- Adjustable range of insulation resistance for positive and negative electrodes: 0–1000 kΩ.
- Positive and negative electrode insulation resistance adjustment step size: 1 kΩ
- Accuracy: ≤±0.5%
- Insulation Resistance: Provides two independent positive and negative insulation resistance channels.
- Adjustable range of insulation resistance for positive and negative electrodes: 0–1000 kΩ.
- Branch line positive and negative terminal-to-ground distributed capacitance parameters
- Adjustable range of the distributed capacitance for the positive and negative terminals of the branch: 0–30 µF
- Step size for adjusting the distributed capacitance of the branch’s positive and negative terminals: 1 µF
- Accuracy: ≤±5%
- Adjustable range of the distributed capacitance for the positive and negative terminals of the branch: 0–30 µF
- System positive and negative terminal-to-ground distributed capacitance parameters
- Adjustable range of the system’s positive and negative electrode distributed capacitance: 0–150 µF.
- System positive and negative electrode distributed capacitance adjustment step size: 10 µF
- Accuracy: ≤±5%
- Adjustable range of the system’s positive and negative electrode distributed capacitance: 0–150 µF.
- Signal Comprehensive Test Parameters
a) Signal amplitude: 10–110 V
- Signal frequency: 0.24 Hz–49.9 Hz
- Display and Touchscreen Specifications
- Display size: 7-inch TFT
- Display resolution: 65,536 colors, 800x480
- Touchscreen resolution: 4096 points
- Display size: 7-inch TFT
- Dimensions: 426 × 194 × 414 mm (Length × Height × Width)
- Weight: 13 kg
Service system
Offering inspection and reception services
We guarantee to welcome your visit at any time and provide you with every possible convenience.
Provide a reasonable quotation.
We guarantee to provide a unified, reasonable quotation for the products you request within 24 hours.
Provide professional technical support
We guarantee that a technical specialist will respond to any technical questions you may have within 24 hours.
Provide detailed information
We guarantee that, within 24 hours, the product catalogues, software CDs, and other technical materials you require will be delivered to your company by our local branch or office.
Related products
Power Technology
2016-04-05
Leave a message for inquiry
Contact Us
National Service Hotline: 400-027-8938
Mobile (Manager Chen): 133 9714 9829
Address: Building No. 5, Donghu High-tech Industrial Innovation Base, No. 9 Miaoshan Avenue, Miaoshan Development Zone, Jiangxia District, Wuhan City
Scan it
Follow the official mobile website