产品名称

ND-9000 Electric comprehensive test vehicle

Affiliate classification
Quantity
-
+
没有此类产品
Product description
Product parameters
  Reference standard: DL/T596-2005, GB50150-2006, GB17691-2005 National IV (chassis).
 
  Features:
  The high-voltage test vehicle is based on the square warehouse Iveco, with the distributed centralized control system as the core. It provides a convenient and comfortable mobile office environment for the staff through humanized modification. It will work the power supply, control system, working platform, test equipment and storage. The cabinets are organically combined to form a mobile test platform centered on the test vehicle.
 
  Scope of application:
  It is suitable for high-voltage electrical test of primary equipment on the substation of 35~220kV voltage level.
 
  The main parameters:
 
NO.
Device name
Specification model
Unit
Quantity
Remarks
1
Iveco square warehouse
NJK5057XJC4 type inspection vehicle
Vehicle
1
Mobile
Platform
2
Vehicle generator
5KW(Yamaha)
Station
1
Jobs
Power supply
UPS smart power supply
Power Star (One machine)
Set
1
Car LAN
Nanxing Power
Set
1
Intelligent
Software
Video surveillance and pan/tilt control software
Nanxing Power
Set
1
Instrument communication software
Nanxing Power
Set
1
4
Power console
Nanxing Power
Set
1
Main console section
PC industrial computer
Advantech
Set
1
LCD Monitor
ASUS 19.5' LED screen display
Set
1
Laser printer
HP 1020(Inkjet)
Set
1
5
Overhead air conditioner
Modified part
Set
1
 
Body modification
Workspace wooden floor
Modified part
Set
1
Lighting system
Modified part
Set
1
Rotating seat
Modified part
Set
1
Safety tool cabinet
Modified part
Set
1
Cable retractor (Electric / Manual)
Modified part
Set
1
6
Power console
Nanxing Power
Set
1
 
 
(With RS232 interface)
Transformer capacity and characteristic tester
Nanxing Power
Set
1
Ratio group tester
Nanxing Power
Set
1
DC resistance tester
Nanxing Power
Set
1
On-load tap-changer tester
Nanxing Power
Set
1
Dielectric loss tester
Nanxing Power
Set
1
Loop resistance tester
Nanxing Power
Set
1
Circuit breaker characteristic tester
Nanxing Power
Set
1
Oxidizing arrester tester
Nanxing Power
Set
1
Frequency conversion resonator
Nanxing Power
Set
1
Insulation Resistance Tester
Nanxing Power
Set
1
(Portable)
DC high voltage generator
Nanxing Power
Set
1
AC and DC voltage divider
Nanxing Power
Set
1
Insulating oil dielectric strength tester
Nanxing Power
Set
1
Wireless high voltage nuclear phaser
Nanxing Power
Set
1
 
  Annex 1: Routine test configuration scheme
  The program is based on DL/T596-2005 “Procedure Test Procedures for Electrical Equipment”, GB50150-2006 “Electrical Equipment Installation Test for Electrical Installations” and the National Energy Administration for Printing and Distributing the “Installation (Repair, Test) Power Facilities License Office” List of documents such as notices for construction equipment conditions (2017 version).
  1. Equipment conditions for construction machinery and equipment required for installation (repair, test) power facility permit
 

 

NO.
Machine equipment name
Unit
Quantity
Specification
Model
One
High voltage generating equipment
1
DC high voltage generator
Set
1
DC:300kV/5mA
NDZGF-300kV/5mA
2
Power frequency withstand voltage test device
Set
1
AC:10kVA/100kV
NDYDJ-10kV/100kV
 
 
Set
1
AC:5kVA/50kV
NDYDJ-5kVA/50kV
3
Complete set of variable frequency series resonance test
Set
1
4000kVA/800kV/5A
30~300Hz
NDBX-F-4000kVA/800kV
4
Partial discharge complete device
Set
1
400KW or more
Frequency greater than 100Hz
NDBX-W-400kW
5
Induction withstand voltage test device
Set
1
5kVA/360V 150Hz
NDSBF-5kVA/360V
Two
Electrical measurement section
1
High voltage dielectric loss tester
Set
2
  1. Media measurement accuracy is 1%
  2. Capacitance accuracy is 0.5%
  3. Anti-interference frequency conversion technology
NDX6000E
2
Loop resistance tester
Set
2
DC:≥100A
NDJR-100A
3
Transformer volt-ampere characteristic tester
Set
1
2200V/1A
NDFA-IV
 
 
Set
1
1100V/5A
NDFA-III
4
Ground Resistance Tester
Set
1
Communication method>3-20A
NDWR-III
 
 
Set
1
Different frequency method
NDWR-III
5
Capacitance inductance tester
Set
1
 
NDCL-III
6
Precision current transformer
Set
2
Level 0.2
 
7
Precision voltage transformer
Set
2
Level 0.2
 
8
Ground conduction tester
Set
1
DC:1A
NDJDT-III
9
Transformer DC resistance tester
Set
2
DC:≥10A
NDR-10A
10
Transformer ratio tester
Set
1
Digital Level 0.5
NDBY-III
11
Transformer winding deformation tester
Set
1
Frequency response method
NDBRY-III
12
On-load tap-changer tester
Set
1
≥1A
NDBYC-2000A
13
Circuit breaker characteristic tester
Set
2
 
NDKC-III
14
Zinc oxide arrester resistive current tester
Set
1
 
NDBL-IV
15
Six-phase relay protection tester
Set
1
Three-phase voltage and current each 2 groups
ND-1200A
16
Transmission line parameter tester
Set
1
Different frequency method
NDXCY-III
17
High current test kit
Set
1
 
NDDG-1000A
18
Online current detection ammeter calibrator
Set
1
 
NDFCZ-III
19
Lightning counter calibrator
Set
1
 
NDFCZ-II
20
Insulation Resistance Tester
Set
2
DC:0~10000V 200GΩ
Short circuit current≥5mA
ND2305A
21
Transmitter calibrator
Set
2
 
ND-RLC-III
22
Gas relay calibration device
Set
1
 
NDMJY-III
Three
Oil and gas test equipment
1
SF6 leak detector
Set
1
Sensitivity 1ppmv
NDXP-1A
2
SF6 gas micro water tester
Set
1
 
NDWS-IV
3
SF6 gas density calibrator
Set
1
Accuracy level 0.2
Pressure range 0~1.0Mpa
NDMJY-III
4
Insulating oil particle size tester
Set
1
 
ND-S40
5
Insulating oil chromatograph
Set
1
 
ND-7860
6
Insulating oil closed flash point meter
Set
1
 
ND-201
7
Insulating oil micro water meter
Set
1
PPM level
NDYWS-III
8
Insulating oil acid value tester
Set
1
 
NDCS-1
9
Insulating oil pH meter
Set
1
 
NDPH-3C
10
Insulating oil automatic dielectric loss and volume resistivity tester
Set
1
 
NDX6100
11
Insulating oil dielectric strength tester
Set
1
 
NDJY-III
Four
Common instrumentation
1
Megohmmeter
Set
2
DC:5000V
ZC-7
2
Megohmmeter
Set
2
DC:2500V
ZC-5
3
Megohmmeter
Set
2
DC:500V
ZC-3
4
DC stabilized current supply
Set
1
220V/110V/5A
WY-II
5
Current transformer secondary loop load tester
Set
1
20V/5A
NDFY-III
6
Three-phase voltage regulator
Set
1
15kVA
TSC-15kVA
7
Digital double clamp phase voltammeter
Set
2
Measuring current 1mA ~ 5A
NDSMG-2000B
 
  2、Construction equipment and equipment required for the installation (repair, test) power facility permit
 
NO.
Machine equipment name
Unit
Quantity
Specification
Model
One
High voltage generating equipment
1
DC high voltage generator
Set
1
DC:250kV/5mA
NDZGF-250kV/5mA
2
Power frequency withstand voltage test device
Set
1
AC:10kVA/100kV
NDYDJ-10kV/100kV
 
 
Set
1
AC:5kVA/50kV
NDYDJ-5kVA/50kV
3
Complete set of variable frequency series resonance test
Set
1
2000kVA/400kV/5A
30~300Hz
NDBX-F-2000kVA/400kV
4
Induction withstand voltage test device
Set
1
5kVA/360V 150Hz
NDSBF-5kVA/360V
Two
Electrical measurement section
1
High voltage dielectric loss tester
Set
2
1、Media measurement accuracy is 1%
2、Capacitance accuracy is 0.5%
3、Anti-interference frequency conversion technology
NDX6000E
2
Loop resistance tester
Set
2
DC:≥100A
NDJR-100A
3
Transformer volt-ampere characteristic tester
Set
1
2200V/1A
NDFA-IV
4
Ground Resistance Tester
Set
1
Different frequency method
NDWR-III
5
Capacitance inductance tester
Set
1
 
NDCL-III
6
Ground conduction tester
Set
1
DC:1A
NDJDT-III
7
Transformer DC resistance tester
Set
2
DC:≥10A
NDR-10A
8
Transformer ratio tester
Set
1
Digital level 0.5
NDBY-III
9
Transformer winding deformation tester
Set
1
Frequency response method
NDBRY-III
10
On-load tap-changer tester
Set
1
≥1A
NDBYC-2000A
11
Circuit breaker characteristic tester
Set
2
 
NDKC-III
12
Zinc oxide arrester resistive current tester
Set
1
 
NDBL-IV
13
Six-phase relay protection tester
Set
1
Three-phase voltage and current each 2 groups
ND-1200A
14
Transmission line parameter tester
Set
1
Different frequency method
NDXCY-III
15
Lightning counter calibrator
Set
1
 
NDFCZ-II
16
Insulation Resistance Tester
Set
2
DC:0~5000V 200GΩ
Short circuit current≥5mA
ND2305A
Three
Oil and gas test equipment
1
SF6 leak detector
Set
1
Sensitivity 1ppmv
NDXP-1A
2
SF6 gas micro water tester
Set
1
 
NDWS-IV
3
SF6 gas density calibrator
Set
1
Accuracy level 0.2
Pressure range 0~1.0Mpa
NDMJY-III
4
Insulating oil chromatograph
Set
1
 
ND-7860
5
Insulating oil closed flash point meter
Set
1
 
ND-201
6
Insulating oil micro water meter
Set
1
PPM level
NDYWS-III
7
Insulating oil acid value tester
Set
1
 
NDCS-1
8
Insulating oil pH meter
Set
1
 
NDPH-3C
9
Insulating oil automatic dielectric loss and volume resistivity tester
Set
1
 
NDX6100
10
Insulating oil dielectric strength tester
Set
1
 
NDJY-III
Four
Common instrumentation
1
Megohmmeter
Set
2
DC:2500V
ZC-5
2
Megohmmeter
Set
2
DC:500V
ZC-3
3
Digital double clamp phase voltammeter
Set
2
Measuring current 1mA ~ 5A
NDSMG-2000B
 
  3、Construction equipment and equipment required for the installation (repair, test) power facility permit
 
NO.
Machine equipment name
Unit
Quantity
Specification
Model
One
High voltage generating equipment
1
DC high voltage generator
Set
1
DC:200kV/3mA
NDZGF-200kV/3mA
 
 
Set
1
DC:120kV/2mA
NDZGF-120kV/2mA
2
Power frequency withstand voltage test device
Set
1
AC:10kVA/100kV
NDYDJ-10kV/100kV
 
 
Set
1
AC:5kVA/50kV
NDYDJ-5kVA/50kV
3
Complete set of variable frequency series resonance test
Set
1
500kVA/200kV/2.5A
30~300Hz
NDBX-F-500kVA/200kV
4
Induction withstand voltage test device
Set
1
5kVA/360V 150Hz
NDSBF-5kVA/360V
Two
Electrical measurement section
1
High voltage dielectric loss tester
Set
2
1、Media measurement accuracy is 1%
2、Capacitance accuracy is 0.5%
3、Anti-interference frequency conversion technology
NDX6000E
2
Loop resistance tester
Set
2
DC:≥100A
NDJR-100A
3
Transformer volt-ampere characteristic tester
Set
1
1100V/5A
NDFA-III
4
Ground Resistance Tester
Set
1
Different frequency method
NDWR-III
5
Capacitance inductance tester
Set
1
 
NDCL-III
6
Ground conduction tester
Set
1
DC:1A
NDJDT-III
7
Transformer DC resistance tester
Set
2
DC:≥10A
NDR-10A
8
Transformer ratio tester
Set
1
Digital Level 0.5
NDBY-III
9
Transformer winding deformation tester
Set
1
Frequency response method
NDBRY-III
10
On-load tap-changer tester
Set
1
≥1A
NDBYC-2000A
11
Circuit breaker characteristic tester
Set
2
 
NDKC-III
12
Zinc oxide arrester resistive current tester
Set
1
 
NDBL-IV
13
Six-phase relay protection tester
Set
1
Three-phase voltage and current each 2 groups
ND-1200A
14
Lightning counter calibrator
1
 
NDFCZ-II
15
Insulation Resistance Tester
Set
2
DC:0~5000V 200GΩ
Short circuit current ≥3mA
ND2305A
Three
Oil and gas test equipment
1
SF6 leak detector
Set
1
Sensitivity 1ppmv
NDXP-1A
2
SF6 gas micro water tester
Set
1
 
NDWS-IV
Four
Common instrumentation
1
Megohmmeter
Set
2
DC:2500V
ZC-5
2
Megohmmeter
Set
2
DC:500V
ZC-3
3
Digital double clamp phase voltammeter
Set
2
Measuring current 1mA ~ 5A
NDSMG-2000B
 
  4、Construction equipment and equipment required for the installation (repair, test) power facility permit
 
NO.
Machine equipment name
Unit
Quantity
Specification
Model
One
High voltage generating equipment
1
DC high voltage generator
Set
1
DC:120kV/2mA
NDZGF-120kV/2mA
2
Power frequency withstand voltage test device
Set
1
AC:30kVA/50kV
NDYDJ-30kV/50kV
 
 
Set
1
AC:6-10kVA/50kV
NDYDJ-6-10kVA/50kV
3
Complete set of variable frequency series resonance test
Set
1
216kVA/216kV/1A
30~300Hz
NDBX-F-216kVA/216kV
4
Induction withstand voltage test device
Set
1
5kVA/360V 150Hz
NDSBF-5kVA/360V
Two
Electrical measurement section
1
High voltage dielectric loss tester
Set
2
1、Media measurement accuracy is 1%
2、Capacitance accuracy is 0.5%
3、Anti-interference frequency conversion technology
NDX6000E
2
Three-phase relay protection tester
Set
1
Three-phase voltage and current each 2 groups
ND-1200A
3
Loop resistance tester
Set
2
DC:≥100A
NDJR-100A
4
Transformer volt-ampere characteristic tester
Set
1
500V/5A
NDFA-III
5
Ground Resistance Tester
Set
1
Different frequency method
NDWR-III
6
Transformer DC resistance tester
Set
2
DC:≥10A
NDR-10A
7
Transformer ratio tester
Set
1
Digital Level 0.5
NDBY-III
8
Circuit breaker characteristic tester
Set
2
 
NDKC-III
9
Insulation Resistance Tester
Set
2
DC:0~5000V 200GΩ
Short circuit current≥3mA
ND2305A
Three
Common instrumentation
1
Megohmmeter
Set
2
DC:2500V
ZC-5
2
Megohmmeter
Set
2
DC:500V
ZC-3
3
Digital double clamp phase voltammeter
Set
2
Measuring current 1mA ~ 5A
NDSMG-2000B
 
  5、Construction equipment and equipment required for the installation (repair, test) power facility permit
 
NO.
Machine equipment name
Unit
Quantity
Specification
Model
One
High voltage generating equipment
1
DC high voltage generator
Set
1
DC:60kV/2mA
NDZGF-60kV/2mA
2
Power frequency withstand voltage test device
Set
1
AC:5kVA/50kV
NDYDJ-5kV/50kV
3
Complete set of variable frequency series resonance test
Set
1
216kVA/216kV/1A
30~300Hz
NDBX-F-216kVA/216kV
Two
Electrical measurement section
1
Loop resistance tester
Set
2
DC:≥100A
NDJR-100A
2
Three-phase relay protection tester
Set
1
Three-phase voltage and current each 2 groups
ND-1200A
3
Transformer volt-ampere characteristic tester
Set
1
500V/5A
NDFA-III
4
Ground Resistance Tester
Set
1
Different frequency method
NDWR-III
5
Transformer DC resistance tester
Set
2
DC:≥10A
NDR-10A
6
Transformer ratio tester
Set
1
Digital Level 0.5
NDBY-III
7
Circuit breaker characteristic tester
Set
2
 
NDKC-III
Three
Common instrumentation
1
Megohmmeter
Set
2
DC:2500V
ZC-5
2
Megohmmeter
Set
2
DC:500V
ZC-3
3
Digital double clamp phase voltammeter
Set
2
Measuring current 1mA ~ 5A
NDSMG-2000B
 
Sales service commitment
 
Stage
Step
Time
Remarks
Pre-sale
Provide information
 
24 hours
Product catalog, running CD and other technical materials
Technical Support
Technical experts answer questions
Reasonable quotation
Uniform and reasonable quotation
Inspection reception
Facilitate user visits at any time
Sale
Signing the contract
Agreement time
Sign a rigorous and scientific purchase and sale contract
Execution of the contract
Strict implementation of contract terms
Provide services
Provide delivery, installation, commissioning, training and other services
After sale
Service Policy
3 Months replacement, free maintenance within 3 years, free lifetime upgrade
Free guidance
On-site installation and commissioning and commissioning of complete sets of equipment
Equipment commissioning
Test device metrics
After-sales tracking
1 year later
Tracking feedback every quarter
Malfunction repair
48 hours
Send technicians to handle the fault
Other service
 
Purchasing spare parts according to user needs

 






Corresponding parameter set not found, please add it in property template of background