产品名称
NDPCY-IV Automatic program-controlled source transformer verification device
Affiliate classification
Transformer detection class
Quantity
-
+
Product description
Product parameters
Reference standards: JJG314-2010, JJG313-2010.
Features:
● Real virtual instrument design, fully automatic control, just operate the mouse and keyboard through the virtual instrument interface on the computer screen, input the transformer type, range, accuracy level, capacity, power factor and other parameters, then complete the measurement To the entire process of printing a certificate;
● Power supply by variable frequency source, fast, stable and accurate fixed point, completely solve the 1% fixed point problem of S-class transformer;
● Voltage and current load box gear program control automatically switches, no manual calculation and manual shifting;
● It has perfect alarm and overcurrent protection function, and can also be used as a power frequency withstand test bench for transformer withstand voltage test.
The main parameters:
Maximum output capacity
|
7kVA
|
Output voltage accuracy
|
1%
|
Range
|
Voltage 100/3V, 100/3V, 100V; Current: 1A, 5A
|
Overcurrent protection setting
|
3A、5A、10A、20A、30A、40A
|
Transformer calibrator section
|
Measurement accuracy: Level 2
|
Δf=±(2%×f +2%×δ±2个字)
|
|
Δδ=±(2%×f +2%×δ±5个字)
|
|
Operating current / voltage dial gauge accuracy
|
± (1.5% × Reading + 2 words)
|
Load impedance generated by the instrument in the standard CT secondary
|
≤0.01Ω,COSΦ≈1
|
The load impedance generated by the instrument in the secondary CT of the test
|
≤0.01Ω,COSΦ≈1
|
The load generated by the instrument in the standard PT secondary (100V)
|
≤0.25VA,COSΦ≈1
|
Polarity indicating action current
|
Rated operating current 2% to 10%
|
Polarity indicating operating voltage
|
Rated working voltage 2% to 10%
|
Working power
|
AC220V±10%,50Hz±1%
|
Measuring range and resolution of the instrument:
Test items
|
Range
|
Resolution
|
f(%)
|
0.0001~20
|
0.0001
|
δ(分)
|
0.001~600
|
0.001
|
Impedance (Ω)
|
0.001~3.5
|
0.001
|
Admittance (MS)
|
0.001~3.5
|
0.001
|
Small current (A)
|
(10-6~5.000×10-2)I
|
10-6I
|
Small voltage (V)
|
(10-6~5×10-2)U
|
10-6U
|