NDSDL-1000A Temperature Rise Test Device

发布时间:2019-08-08


NDSDL-1000A Temperature Rise Test Device
I. Technical Specifications
1. Main body of the NDSDL-24 kVA/1000 A high-current generator
The main body of the high‑current generator consists of three single‑phase, 8 kVA output transformers. The specifications for each unit are as follows:
Single-unit capacity: 8 kVA (Total capacity: 24 kVA)
Input power: AC 220 V (one neutral wire and one live wire)
Input current: 36.4 A
Output open-circuit voltage: 8 V
Output current: 1000A
Operating time: 30 minutes, interval operation
Cooling method: Natural cooling
For three individual transformers, the winding polarities and winding directions must be identical; the impedance deviation of each unit shall be less than 3%; and both the input and output connections shall be star‑connected.
2. The accompanying NDTC-24 kVA/1000 A control console consists of:
The control console for the three-phase high-current generator comprises one 24 kVA three-phase contact-type voltage regulator, three 0.5 kVA fine‑adjustment voltage regulators, three 0.5 kVA fine‑adjustment transformers, and main control electrical components. It features an aluminum alloy panel and a 1000 A digital display meter. The main technical parameters are as follows:
Total actual configured three-phase capacity: 24 kVA
Input power: three-phase four-wire, 380 V
Input current: 36.4 A
Output phase voltage: 0–220 V (adjustable)
Single-phase voltage unbalance: 20%
The input power supply is connected in a star configuration.
The output voltage is a three-phase star-connected output.
Current resolution: 1 A
Cooling method: Natural cooling
3. Composition of console accessories:
Four 16-square‑mm power cables
One grounding wire
Four 3-meter-long, 400-square‑mm high‑current output cables.
 