1. Flexible combination of voltage and current outputs. Output up to 6 Phase voltage 6 Phase current , Can be freely combined to achieve standard functionality. 4 Phase voltage 3 Phase current type, 6 Phase-voltage type, 6 Phase current type, and 12 Phase-type output mode , It is compatible with all conventional testing methods.
2. The standalone operation is convenient. The device’s front panel features a trackball mouse, an optimized keyboard, and a large display. TFT Liquid crystal display , Built-in all Chinese Windows Platform operating software. Ready to use right out of the box. , Easy and quick to operate.
3. Dual operating modes. In addition to standalone operation, the device can also be connected to a laptop or desktop computer for control. , The two methods offer identical functionality, providing a truly comprehensive dual‑operation mode.
Rated parameters
— AC current output
6 Phase current During output Per-phase output (RMS) 0 ~ 3 0A Output precision 0.2 level
3 Phase current During output Per-phase output (RMS) 0 ~ 60A
6 Parallel current output (RMS) 0 ~ 180A
Long-term permissible operating value (RMS) of phase current 10A
Maximum output power of phase current 300VA
6 Maximum output power at maximum current output in parallel connection. 1000VA
6 Permissible operating time at maximum parallel current output 10s
Frequency range (fundamental) 20 ~ 1000 Hz
Harmonic order 1 ~ 20 Next
— Direct current output
Current output 0 ~± 10 A / Each phase Output precision 0.5 level
Maximum Output Load Voltage 20 V
— AC voltage output
Phase voltage output (RMS) 0 ~ 120V Output precision 0.2 level
Line voltage output (RMS) 0 ~ 240V
Phase voltage / Line voltage output power 80VA / 100VA
Frequency Range (Fundamental) 20 ~ 1000 Hz
Harmonic order 1 ~ 20 Next
— DC voltage output
Phase voltage output amplitude 0 ~± 160V Output precision 0.5 level
Line voltage output amplitude 0 ~± 320V
Phase voltage / Line voltage output power 70VA / 140VA
— Digital signal
8 Digital input for the road
Normally open contact 1 ~ 20mA,24V
Potential contact connection “ 0”:0 ~ +6V ; “ 1”: +11 V ~ +250 V
4 For discrete output signals DC :220 V / 0.2 A ; Air conditioning :220 V / 0.5 A
— Time measurement range
0.1 m s ~ 9999s , Measurement Accuracy < 0.1mS