undefined

undefined

Product Center


MengziNDWS Series Transformer Temperature Rise Test System

Category:

MengziTransformer Testing Series

Phone: 0512-66101666

Product Description

Technical Specifications (Temperature Controller)
10.1-inch color TFT touch LCD or 7-inch color TFT touch LCD
There are four basic display screens: digital display, bar graph display, real-time curve display, and historical curve display. The basic measurement error is less than ±0.2% of full scale, and the digital display range is –999.99 to 1999.99.
Measurement resolution: 1/60,000, 24-bit ADC
The real-time curve recording interval ranges from 1 second to 9,999 seconds, corresponding to a full-screen curve duration of 30 seconds to 300 minutes.
The recording interval of the memory curve can be continuously set from 1 second to 9,999 seconds. Relay output: contact rating is AC 220 V, 3 A; for resistive loads, the load resistance must exceed 2 kΩ. Sixteen output channels are user‑configurable and can be programmed according to the alarm threshold values of each channel. Voltage output impedance: —. DC 24 V power supply: used to power the transmitter, with a maximum current capacity of ≤200 mA.
·Optoelectronic isolation
Standard configuration includes RS232 and RS485 communication; Ethernet communication requires specifying the baud rate—9600, 19200, 57600, or 115200—at the time of order, selectable via settings. · Comes with dedicated test software, providing parameter‑setting tools and application‑level technical support.
·Optional Modbus RTU communication protocol for communication with the host computer
Instruments powered by AC 220 V: AC 85–265 V, with power consumption less than 25 VA. Instruments powered by DC 24 V: 24 V ±10%, with power consumption less than 25 VA. Note: Actual power consumption depends on the total number of channels of the instrument.
Operating temperature range: 0°C to 50°C
Storage temperature range: -20°C to 70°C
Operating humidity range: below 85% RH, no condensation.
Instrument weight (64 channels): approximately 3.8 kg max.

 

 

Technical Specifications (Dual-Channel DC Resistance Meter)

  1. High-voltage side output current: <5mA, 40mA, 200mA, 1A, 5A

Low-voltage side output current: 2A, 5A, 10A, 20A

  1. Range:

High-voltage side:

  • 1 mΩ to 2 Ω (5 A)
  • 5 mΩ to 10 Ω (1 A)
  • 100 mΩ to 50 Ω ( 200mA )
  • 1Ω~250Ω ( 40mA )
  • 10Ω~20kΩ ( <5mA )

Low-pressure side:

  • 100 μΩ to 500 mΩ (20 A)
  • 200 μΩ to 1 Ω (10 A)
  • 1 mΩ to 1.6 Ω (5 A)
  • 5 mΩ to 4 Ω (2 A)
  1. Accuracy: ±(0.2% + 2 digits)
  2. Resolution: 0.1 μΩ
  3. Operating temperature: 0–40°C
  4. Ambient humidity: ≤90% RH, no condensation
  5. Power supply: AC 220 V ±10%, 50 Hz ±1 Hz
  6. External dimensions: 440×240×390
  7. Net weight: 15 kg

Welcome to leave us an online message; we will get back to you promptly.

%{tishi_zhanwei}%