MengziND7860 Series Transformer Oil Chromatography Analyzer
Category:
MengziInsulating Oil and SF6 Gas Testing Equipment
Phone: 0512-66101666
Product Description
■ Product Overview
The transformer oil chromatography analyzer is suitable for determining the concentrations of dissolved gas components in insulating oil used in power systems, and a single injection is sufficient to analyze the dissolved gases in the insulating oil. 7 Gas component species H2、 CO 、CO2、CH4、C2H4、C2H6、 C2H2( Hydrogen, carbon monoxide, carbon dioxide, methane, ethylene, ethane, acetylene ) A comprehensive analysis of the content, with a minimum detection limit for acetylene reaching 0.1ppm . [Main Testing] :H2 、 CO 、CO2、CH4、C2H4、C2H6、C2H2 As the primary basis for fault diagnosis , It is recommended to test whenever possible. :02 、N2 As an auxiliary judgment ( That is 9 Type of gas )。
■ Product Ingredients
Name | Component | Minimum detection concentration /uL/L |
Methane | CH4 | 0.1 |
Ethylene | C2H4 | 0.1 |
Ethane | C2H6 | 0.1 |
Acetylene | C2H2 | 0.1 |
Hydrogen gas | H2 | 2 |
Carbon monoxide | CO | 1 |
Carbon dioxide | CO2 | 5 |
■Product Features
1. Online monitoring H2、 CO 、CH4、C2H4、C2H6、C2H2、CO2、 H20( Optional equipment ) Gas concentration and growth rate :
2. Rapid analysis cycle, with a minimum monitoring interval of 1 hour , Longest 30 Heaven , Users can configure it themselves. ( Recommended as 24 hour )
3. A cyclic sampling method is employed, thereby avoiding any loss of transformer oil due to discharge. ;
4. A vacuum environment and magnetic stirring are employed to achieve rapid oil–gas separation, with a stable degassing rate. ;
5. Employing an exclusive patented cold-trap technology, it completely isolates hydrocarbon contamination, enabling maintenance-free operation of on-site equipment throughout its entire service life.
6. By employing a dedicated high-performance monolithic chromatographic column, the system’s analytical reliability is enhanced, making it suitable for the long-term safe operation of field‑based outdoor equipment.
7. Adopting internationally advanced MEMS Integrated sensor technology, with high detection sensitivity, long service life, and a stable baseline. ;
8. High-stability, high-precision gas detection technology and computational models, with an error margin of ± 10% , superior to offline chromatographs ± 30% of the indicator
9. Adopt TCP/IP Network protocol that enables remote monitoring and diagnostics, as well as remote data browsing and access. ;
10. Automatically identify peak positions in fault gas characteristic curves and perform analysis of the raw spectra.
11. Multiple data display and query methods are provided, along with data reporting and trend chart analysis.
12. Provides multiple fault diagnosis methods, including the improved three-ratio method, the David triangle method, and the cubic diagram method.
13. Equipped with an equipment anomaly alarm function, it significantly enhances the reliable and safe operation of the equipment. ;
14. Installation and maintenance are straightforward; the entire equipment can be installed live without disrupting the transformer’s normal operation.
■ Product Specifications
Technical Specifications | Detailed specifications |
Hydrogen Flame Ionization Detector | Detection limit :Mt ≤ 3x10-12 g/s( n-Hexadecane - Isooctane solution ) |
Noise : ≤ 5x10-14A | |
Drifting : ≤ 1x10-13A/30min | |
Linear range : ≥ 106 | |
Thermal Conductivity Detector | Sensitivity :S ≥ 3500 mV/mI/mg( Routine )5000 mV/mL/mg( High sensitivity ) |
Noise : ≤ 10 mu V | |
Baseline drift : ≤ 30 mu V/30min | |
Linear range : ≥ 104 | |
Column oven temperature control | Temperature control range : Above room temperature 4~450 °C |
Temperature control accuracy : ± 0.1 °C | |
Packed-column injector | Temperature control range : Above room temperature 4~450 °C |
Temperature control accuracy : ± 0.1 °C | |
Hydrogen flame (FID) Detector | Temperature control range : Above room temperature 4~450 °C |
Temperature control accuracy : ± 0.1 °C |
■Product Selection Specification Table
Model number | Functional Parameters |
ND7860 | Headspace sampler model ,H2 、 CO 、CO2、CH4、C2H4、C2H6、 C2H2(7 seed ) |
ND7861 | ( For ethylene oxide use only ) Fully automatic type |
ND7862 | ( For ethylene oxide use only ) Semi-automatic type |
ND7863 | Nine-component methane CH4 Ethylene C2H4 Ethane C2H6 Acetylene C2H2 Hydrogen gas H2- Carbon monoxide CO Carbon dioxide C02 Oxygen 02 Nitrogen gas N2 |