MengziNDX6000 Series Fully Automatic Anti-Interference Dielectric Loss Tester
Category:
MengziTransformer Testing Series
Phone: 0512-66101666
Product Description
■ Product Overview
Dielectric loss measurement is a fundamental method in insulation testing, capable of effectively detecting overall moisture ingress and degradation of electrical equipment insulation. , as well as localized defects. It is widely used in electrical manufacturing, electrical equipment installation and handover, and preventive testing. Measuring the dielectric loss of transformers, instrument transformers, reactors, capacitors, bushings, surge arresters, and other components is the most fundamental method for assessing their insulation performance. By employing variable-frequency power‑supply technology and leveraging microcontrollers and modern electronic techniques, automatic frequency conversion and analog… / Number conversion and data operations , It achieves strong anti-interference capability, fast testing speed, high accuracy, fully automated digitalization, and simple operation. ; The power supply uses a high-power switching power supply. , Output 45Hz and 55Hz Pure sine wave , Automatic pressurization , Can provide up to 10kV the voltage ; Automatic filtering 50Hz Interference—suitable for on-site testing in environments with significant electromagnetic interference, such as substations.
■ Technical Specifications
Accuracy | Cx: ± ( Reading x1%+1pF) | tan delta : ± ( Reading x1%+0.00040) | ||
Anti-interference performance indicator | Variable-frequency anti-interference, in 200% It can still achieve the aforementioned accuracy under interference. | |||
Capacitance range | Internal high pressure | 3pF-60000pF/10kV 60pF~1 mu F/0.5kV | ||
External high voltage application | 3pF~1.5 mu F/10kV60pF-30uF/0.5kV | |||
Resolution | 0.001pF,4 significant figures | |||
lg5 Scope | Unlimited, resolution 0.001% , Automatic identification of three types of test samples: capacitors, inductors, and resistors. | |||
Test current range | 10 mu A~1A | |||
Internal high pressure | Set the voltage range | 0.5~10kV | Maximum output current | 200mA |
Buck-boost method | Continuous smooth adjustment | Frequency accuracy | ± 0.01HZ | |
Test frequency | 45、50、55、60、65Hz Single frequency | |||
45/55H2、55/65Hz、47.5/52.5Hz Automatic dual-frequency inverter | ||||
External high voltage application | Maximum test current in positive wiring 1A , power frequency or variable frequency 40-70Hz Maximum test current during reverse wiring 10KV/1A , power frequency or variable frequency 40-70Hz | |||
CVT Self-excitation method low-voltage output | Output voltage 3~50V , output current 3~30A | |||
CVT Turns Ratio Measurement | Turns-ratio measurement accuracy | ± reading x1% | Turns-ratio measurement range | 10~99999 |
Phase measurement | Phase measurement accuracy | ± 0.1 ° | Phase measurement range | 0-359. 9 ° |
Measurement time | Approximately 40s , related to the measurement method | Computer interface | Standard RS232 Interface | |
Input power supply | 180V~270VAC ,50Hz ± 1% , powered by mains electricity or a generator | |||